THE MINELABGP extreme
29
OPERATION
5
DETAILED OPERATING INSTRUCTIONS
Turn the GP extreme On
Hold the coil away from the ground and metal objects and switch
Power to On.
NOTE When theGP extreme is turned Off, important
information (e.g. tuning frequency and ground balance) is
saved in internal memory.
If detection recommences in the same location, the user
should not have to re-tune or re-ground balance the
detector.
Set the Volume Control
Volume should be set so that target signals are clear and easy to
hear but loud signals are not uncomfortable to your hearing.
Set Volume by testing volume levels by passing coil across a large
target and setting volume at comfortable level. Now test very small
target at this level.
Set the Threshold control
Adjust the Threshold control until the threshold is just audible
through the headphones.
NOTE Small surface objects, as well as large deep objects,
will produce very small changes in the threshold. It is
important to set the Threshold control correctly to ensure
that these targets are heard. Experiment with known targets
to assist in setting all controls to suit your hearing.
DETAILED OPERATING INSTRUCTIONS
HINT
Take time to read this manual
thoroughly to obtain the best
performance from your new
GP extreme detector.
THE MINELABGP extreme
28
OPERATION
5
www.minelab.com
QUICK START INSTRUCTIONS (EASY REFERENCE)
easy reference
STEP 1 Turn Power switch On.
STEP 2 Set Boost to N (Normal) for general detecting.
STEP 3 Set Volume to maximum, and Signal to midway.
STEP 4 Adjust the Threshold control so that a faint sound is heard
through the headphones.
STEP 5 Adjust Tone for threshold level that suits your hearing.
STEP 6 To tune the detector, hold at waist height with the shaft
horizontal. Keep the coil vertical.
STEP 7 Slowly move coil around your body through a half-circle
until the noise from interference is loudest.
STEP 8 Hold this position, keep the coil motionless and push the
Tune switch once to start the tuning function.
STEP 9 Tuning takes approximately 60 seconds. A series of three
beeps will indicate that the optimum frequency has been
selected.
STEP 10 For Discrimination, change the Iron Discriminate
switch to Disc and set Level Adjust to the middle of its
range.
STEP 11 Set Soil switch to N (normal)
STEP 12 Set Rx switch to Normal
STEP 13 Set the Ground Balance by moving the coil up and down.
While coil is in motion, change Balance switch from Fixed
to Tracking
.
STEP 14 The detector is now ready for operation.