Minelab GP 3500 User Manual Page 20

  • Download
  • Add to my manuals
  • Print
  • Page
    / 30
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 19
front controls
– continued
page 32
l 4 controls and operation l
GP 3500
page 32
Tracking Speed
If searching in Tracking position, the operator can choose the speed that
is best suited to the area. In effect, this gives the operator 4 options to
search in: Slow, Medium & Fast plus the 4th being Fixed Balance which
is the recommended position subject to variability of the ground mineral-
ization.
NOTE – The Tracking Speed switch does not effect the speed of
the initial very fast auto-ground balance. This very fast initial
ground balance only lasts 5 seconds.
If the area being detected has the mineralization changing too often for
the operator to search in Fixed position, the GP 3500 now allows the
operator to gradually step through from Slow auto-tracking, into Medium
speed, then into Fast auto-tracking.
Choosing the preferred speed of tracking should be simply stepping
through the speeds from Slow through to Fast, with the preferred speed
being the slowest speed which still keeps up with the variability of the
ground mineralization.
Tracking
Speed
Figure 4.25
Tracking
speed
front controls
– continued
l 4 controls and operation l
page 33
GP 3500 GP 3500
www.minelab.com
page 33
Quick-Trak push button
Located in the handle of the GP 3500 is a push button which allows easy operation of
ground balancing.
The Quick-Trak push button has two functions depending on where the balance switch is set
on the control box.
If set to Fixed mode:
If the Balance switch on the control box is set into the Fixed position, the detector will
operate with Fixed ground balance while detecting. When the ground mineralization changes
and the operator needs to rebalance, by holding in the Quick-Trak push button, a 5 second
fast rebalance will occur. Once this has been completed, the push button can be released
and the operator can continue detecting in Fixed mode.
If set to Tracking mode:
If the Balance switch on the control box is set to Tracking, the detector will continuously
test and change ground balance to compensate for changes in the ground mineralization,
(the speed of this is controlled by the Tracking speed switch). If a target signal is heard,
the operator can change into Fixed mode by pressing and holding in the Quick-Trak push
button and while the the button is depressed, the detector will operate in Fixed mode for
better pinpointing.
On release of the button a short “beep” will be heard
and a quick auto-ground balance is initiated prior to
returning to Tracking Mode.
NOTE – The Quick-Trak
push button is only
engaged and changing
the operating mode
while the button is
depressed. Once the
button is relaxed, the
Balance mode returns
to that selected on
the control box.
Figure 4.26
Quick-Trak
Push Button
Page view 19