c. To refit the armstrap use Figure 43 as a guide:
Figure 43: Lacing the Armstrap (View from Coil)
3.9 Shafts. The following procedures detail shaft disassembly/assembly and should be
followed in order until the component to be replaced is accessible. Figure 44 illustrates the
components of the shaft assembly.
U
pp
er Camlock Assembl
y
Middle Camlock Assembl
y
U
pp
er Shaft
Yoke and Lower
Camlock Assembly
Figure 44: Shaft Assembly Components
a. To disassemble lower camlock and lower shaft:
Remove the electronics pack (Section 3.3.a) and coil (Section 3.4.a)
Using Figure 45 as a guide, use the 3mm T handle hex driver from the Tool Kit to
push out the two lower camlock pins (Part 5).
Remove the lower camlock body (Part 1) from the lower shaft.
Remove the lower shaft by pushing it back through the upper/middle shafts.
Lower Shaft