Minelab F3 Service Manual Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 42
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
F3 Field Service Manual
Page 40
4. Fault Finding Procedures
4.1 Introduction. A functional test failure (Section 2.2) can generally be repaired by
replacing one or all of the following line replaceable units:
Coil
Wiring Loom
Electronics Pack
a. The F3 is designed so that line replaceable units can be exchanged between
detectors without the need to calibrate. This means that where spare parts are not available
and more than one detector is faulty, then parts from one detector can be used to make
another serviceable. For example, if detector # 1 has an unserviceable coil and detector # 2
has an unserviceable electronics pack, then the coil from detector # 2 can replace the coil on
detector # 1 thereby producing a serviceable detector.
b. Whenever a line replaceable unit is exchanged, follow the applicable procedure
described in Section 3.
c. Where the source of a fault is unknown, due to the ease of replacement it is
recommended that line replaceable units be exchanged in the following sequence:
Electronics Pack
Coil
Wiring Loom
4.2 Trouble Shooting Table. The following table identifies a number of faults and
provides recommended solutions. The suggested solutions should be investigated in the
order they are listed.
Problem Recommended Solutions
F3 will not switch on check batteries are installed correctly
replace batteries with fresh batteries
remove and refit battery pack
replace battery pack
replace wiring loom
replace electronics pack
F3 will not switch off remove battery pack and refit
check magnet on ON/OFF slide has not been dislodged and
connected to the wiring loom overmould
replace wiring loom
replace electronics pack
After switching on
the F3 makes no
sound from speaker
check for tone using the earset
if there is tone through earset - replace speaker pod
if there is no tone through earset - replace wiring loom
if there is no tone through earset - replace electronics pack
Threshold tone is
intermittent
(including LEDs for
F3L)
replace wiring loom
Threshold Tone is
too loud
ensure area is free from local electromagnetic interference
conduct Audio Reset
conduct Noise Cancel
replace coil
replace electronics pack
replace wiring loom